Mold on the bathroom ceiling: venting the fan outside, in Montgomery County, PA

Updated

Mold on a bathroom ceiling most often means the steam has nowhere to go. The fix is a fan that moves enough air and a duct that ends outside the house instead of in the attic. On the bathrooms we remodel, the fan duct runs outside, and an old fan can be vented as part of a home repair list.

Why does mold grow on a bathroom ceiling?

Shower steam settles on the ceiling and stays wet. Warm, damp air rises, meets the cooler ceiling and turns back into water, and a ceiling that stays damp is where the black spots start.

The EPA’s guide to mold and moisture asks homeowners to keep indoor humidity below 60 percent, and ideally between 30 and 50 percent. A bathroom right after a hot shower is far above that, so the air has to leave the room, and leave the house, before it settles.

On a basement bathroom we built, the outside wall was cold, so we covered it in foam board and sealed the seams and cracks with spray foam. That keeps warm, damp air from condensing on the cold wood behind the wall, which can lead to mold. A ceiling works the same way, and a cold spot on it stays wet longest.

What does the code require for a bathroom fan?

Pennsylvania’s Uniform Construction Code builds on the International Residential Code. The 2018 edition says four things about a bathroom.

A window or a fan. Section R303.3 asks for at least 3 square feet of window in a bathroom, half of it able to open. Without that, the room needs a light and an exhaust fan.

The fan’s air goes straight outdoors. The same section says the exhaust air from the room goes directly to the outdoors.

Not into the attic. Section M1501.1 says exhaust air cannot be dumped into an attic, a soffit, a ridge vent or a crawl space. A duct that stops in the attic puts the steam right above your ceiling.

Enough air. Table M1505.4.4 sets the minimum for a bathroom at 50 cubic feet a minute for a fan you switch on, or 20 for one that runs all the time.

Where does the fan duct go on our bathrooms?

The fan duct on our bathrooms takes the shortest clean path outside, and the house decides which path that is.

In the basement bathroom, the fan is an 80 cubic foot a minute model, well over the code’s 50. Its duct runs out through the rim joist, the band of framing that sits on top of the foundation wall, and through the siding, with a louver on the outside so the flap closes when the fan is off.

On one bathroom in Montgomery County, the duct ran along the joists and out the back of the house instead of cutting across them to reach the wall. It is a cleaner run, and it keeps the joists solid, since every hole bored through a joist takes strength out of the floor. That fan also went on a new 15 amp circuit from the panel, shared only with the bathroom’s lights.

On another bath, we cut the ceiling open to run the electric line and the vent pipe for the new fan, then hung new drywall and spackled, primed and painted it.

A working exhaust fan is one of the first things we look for on a shower walkthrough, because the code wants one on a shower, and a new tiled shower with no way to dry out starts the same problem over.

What can you check before you call anyone?

Run the fan every shower.

The EPA says to run the bathroom fan or open the window when you shower. A fan that sits off does nothing.

Find where the air comes out.

With the fan running, go outside and look for a flap or a roof cap that moves. If nothing outside moves, the air may be going into the attic, or the duct may have come loose.

Look in the attic.

A duct that ends loose over the insulation, or a damp stain around the fan, means the duct needs to run outside.

Measure the humidity.

A small humidity gauge from the hardware store tells you whether the room comes back under 60 percent after a shower.

Clean small spots, call for big ones.

The EPA says a homeowner can usually clean mold covering less than about 10 square feet, about a 3 foot by 3 foot patch. Past that, or after water damage, it points to someone with mold cleanup experience.

Bathroom fan questions

Can a bathroom fan vent into the attic?

No. The code says exhaust air cannot go into an attic, a soffit, a ridge vent or a crawl space. The duct has to end outside, through the roof or a wall.

Does a window count instead of a fan?

Under the code, yes, with at least 3 square feet of window and half of it able to open. In a Pennsylvania winter that window mostly stays shut, so the bathrooms we build get a fan.

How big a fan does a bathroom need?

The code minimum is 50 cubic feet a minute for a fan you switch on. The basement bathroom we built got an 80, since its duct had a run to make before it reached the outside wall.

Can you vent our old fan outside?

Yes. A fan and its duct can go on a home repair list. You get a written price for your list, and a list starts at $1,500. In a full bath remodel, the fan and its duct are part of the starting price, which is $20,000 for a simple bath in its existing layout.